Panel Equipment - Resistance Temperature Sensor - Merek YAMARI Thermocouple, RTD/PT100 & Thermowell Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50) in a metallic protection tube or thermowell which is joined to a terminal box.
The Model RM uses a drawn protection tube. Versions are available for pipe threads mounting or mounting by a fixed or movable flange. The Model RM is most widely used for general processes.
Model RH uses a thermowell - straight or tapered tubes are available - and fixed flange or pipe threads mounting. Since the Model RH RTS is much stronger than the Model RM, it is suitable for use in high-pressure processes. The operating temperature range depends on the resistance element; -200 to +100 .C, 0 to +300 .C or 0 to +500 .C. The Model RM-00 is the resistance element and lead-wires alone.
These RTSs conform to JIS standards. RTSs conforming to IEC or DIN standards are also available to order. |